medtronic vulnerabilities, newest first
Filter
By year: all 2026 2025 2024 2023 2022 2021
- 6.8CVE-2025-4397EPSS 0.1%
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.
- 6.8CVE-2025-4386EPSS 0.2%
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.
- 3.1CVE-2025-12997EPSS 0.2%
Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive u…
- 4.1CVE-2025-12996EPSS 0.1%
Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.
- 9.8CVE-2025-12995EPSS 0.4%
Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: befo…
- 5.3CVE-2025-12994EPSS 0.3%
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December…
- 6.8CVE-2025-4395EPSS 0.3%
Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patie…
- 6.8CVE-2025-4394EPSS 0.2%
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before…
- 6.5CVE-2025-4393EPSS 0.2%
Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects M…
- 8.8CVE-2023-31222EPSS 28%
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system ca…
- 6.8CVE-2023-25931EPSS 0.3%
Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthori…
- 4.8CVE-2022-32537EPSS 0.4%
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless …
- 8.1CVE-2020-27252EPSS 3.8%
Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could …
- 9.8CVE-2020-25187EPSS 3.9%
Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap ove…
- 8.8CVE-2020-25183EPSS 0.8%
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vul…
- 7.5CVE-2019-13543EPSS 2.0%
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard…
- 7.8CVE-2019-13539EPSS 0.3%
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorith…
- 4.6CVE-2019-13535EPSS 0.4%
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mech…
- 4.6CVE-2019-13531EPSS 0.4%
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mech…
- 7.1CVE-2019-10964EPSS 1.2%
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not pro…
- 6.5CVE-2019-6540EPSS 0.2%
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Co…
- 6.5CVE-2019-6538EPSS 0.9%
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Co…
- 4.6CVE-2018-18984EPSS 0.3%
Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest .
- 4.8CVE-2018-10634EPSS 0.5%
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
- 4.4CVE-2018-10626EPSS 0.4%
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information …
- 5.2CVE-2018-10622EPSS 0.4%
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
- 6.3CVE-2018-10631EPSS 0.4%
The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including…
- 6.4CVE-2018-8870EPSS 0.4%
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain pr…
- 6.2CVE-2018-8868EPSS 0.3%
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An a…
- 7.1CVE-2018-10596EPSS 1.3%
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initial…
- 4.6CVE-2018-8849EPSS 0.3%
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.
- 4.8CVE-2018-5448EPSS 0.7%
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
- 4.9CVE-2018-5446EPSS 0.4%
Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.
- –CVE-2011-3386EPSS 1.5%
Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecifi…