CVE-2011-3386 medtronic paradigm wireless insulin pump
medtronic paradigm wireless insulin pump: no CVSS score yet. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.
Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk of deliberate, malicious, or unauthorized manipulation of medical devices is extremely low... we strongly believe it would be extremely difficult for a third-party to wirelessly tamper with your insulin pump... you would be able to detect tones on the insulin pump that weren't intentionally programmed and could intervene accordingly."
- EPSS
- 1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 74th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
- Published
- Modified
- NVD analysis
- Analyzed, since modified
- Record from
- the NVD, synced
Ask an AI about this CVE
Show the prompt
Explain CVE-2011-3386 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2011-3386?via=ask-ai-copy and https://cve.bz/cve/CVE-2011-3386?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2011-3386 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Affected
Versions
From the NVD's CPE matches.
| Product | Affected |
|---|---|
| medtronic:paradigm_wireless_insulin_pump | 512 |
| medtronic:paradigm_wireless_insulin_pump | 522 |
| medtronic:paradigm_wireless_insulin_pump | 712 |
| medtronic:paradigm_wireless_insulin_pump | 722 |
References
- http://sixuntilme.com/blog2/2011/08/hacked_jay_radcliffe_insulin_p.html
- http://www.darkreading.com/security/vulnerabilities/231300312/getting-root-on-the-human-body.html
- http://www.foxnews.com/scitech/2011/08/04/insulin-pumps-vulnerable-to-hacking/?test=faces
- http://www.hanselman.com/blog/HackersCanKillDiabeticsWithInsulinPumpsFromAHalfMileAwayUmNoFactsVsJournalisticFearMongering.aspx
- http://www.informationweek.com/news/security/vulnerabilities/231600265
- http://www.loop-blog.com/Blog_Full_Post?id=a09C000000Dbz3JIAR
- http://www.scmagazineus.com/black-hat-insulin-pumps-can-be-hacked/article/209106/
- https://exchange.xforce.ibmcloud.com/vulnerabilities/69643