cve.bz

CVE-2019-6540 medtronic

6.5 mediumEPSS 0.2%

Medium (6.5) in medtronic. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

Severity

CVSS 3.1

6.5 medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 9th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-319 Cleartext Transmission of Sensitive Information
OWASP Top 10
A04:2025 Cryptographic Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2019-6540 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-6540?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-6540?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-6540 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Medtronic Conexus Radio Frequency Telemetry ProtocolAll versions
Medtronic MyCareLink Monitor24950
Medtronic MyCareLink Monitor24952
Medtronic CareLink Monitor2490C
Medtronic CareLink 2090 ProgrammerAll versions
Medtronic Amplia CRT-DAll versions
Medtronic Claria CRT-DAll versions
Medtronic Compia CRT-DAll versions
Medtronic Concerto CRT-DAll versions
Medtronic Concerto II CRT-DAll versions
Medtronic Consulta CRT-DAll versions
Medtronic Evera ICDAll versions
Medtronic Maximo II CRT-DAll versions
Medtronic Maximo II ICDAll versions
Medtronic Mirro ICDAll versions
Medtronic Nayamed ND ICDAll versions
Medtronic Primo ICDAll versions
Medtronic Protecta ICD, Protecta CRT-DAll versions
Medtronic Secura ICDAll versions
Medtronic Virtuoso ICDAll versions
Medtronic Virtuoso II ICDAll versions
Medtronic Visia AF ICDAll versions
Medtronic Viva CRT-DAll versions
Medtronic Brava CRT-DAll versions
Medtronic Mirro MRI ICDAll versions

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSMA-19-080-01Medtronic Conexus Radio Frequency Telemetry Protocol (Update C)2019-03-21Healthcare and Public HealthMyCareLink Monitor: Versions 24950 and 24952, Brava CRT-D: (all models), Amplia CRT-D: (all models) and 19 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-65 Sniff Application Code Likelihood: Low · Severity: High
  • CAPEC-102 Session Sidejacking Likelihood: High · Severity: High
  • CAPEC-117 Interception Likelihood: Low · Severity: Medium
  • CAPEC-383 Harvesting Information via API Event Monitoring Severity: Low
  • CAPEC-477 Signature Spoofing by Mixing Signed and Unsigned Content Likelihood: Low · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON