cve.bz

CVE-2017-7574 schneider-electric: Use of Hard-coded Credentials

9.8 criticalEPSS 1.3%

Critical (9.8) in schneider-electric. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.

On this page
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 71st percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2026-05-29. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-798 Use of Hard-coded Credentials
CWE-321 Use of Hard-coded Cryptographic Key
OWASP Top 10
A04:2025 Cryptographic Failures, A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2017-7574 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2017-7574?via=ask-ai-copy and https://cve.bz/cve/CVE-2017-7574?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2017-7574 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:modicon_tm221ce16r_firmware1.3.3.3
schneider-electric:somachine1.4:sp1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-17-103-02ASchneider Electric Modicon M221 PLCs and SoMachine Basic (Update A)2017-04-13All Modicon M221 PLCs with: firmware version up to v1.5.0.1 and associated SoMachine Basic software (up to v1.5), SoMachine Basic: > 1.5none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-70 Try Common or Default Usernames and Passwords Likelihood: Medium · Severity: High
  • CAPEC-191 Read Sensitive Constants Within an Executable Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON