cve.bz

CVE-2025-40806 siemens gridscale x prepay: Observable Response Discrepancy

6.9 mediumEPSS 0.5%

Medium (6.9) in siemens gridscale x prepay. EPSS 0.5% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in Gridscale X Prepay (All versions < V4.2.1). The affected application is vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users.

Severity

CVSS 4.0

6.9 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS 3.1

5.3 medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS
0.5% (unchanged from 0.5% a week ago; 0.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 41st percentile. Scored 2026-11-15. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2025-12-09. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-204 Observable Response Discrepancy
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2025-40806 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-40806?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-40806?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-40806 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Badge for a README or a site

CVE-2025-40806

An image that stays current: it is drawn from the data each time it is fetched (a host that proxies images, as GitHub does, may show its copy for a while). Markdown:

[![CVE-2025-40806](https://cve.bz/cve/badge/CVE-2025-40806.svg)](https://cve.bz/cve/CVE-2025-40806)

HTML:

<a href="https://cve.bz/cve/CVE-2025-40806"><img src="https://cve.bz/cve/badge/CVE-2025-40806.svg" alt="CVE-2025-40806"></a>

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens Gridscale X Prepaybefore V4.2.1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-345-09Siemens Gridscale X Prepay2025-12-09EnergyGridscale X Prepaynone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-331 ICMP IP Total Length Field Probe Likelihood: Medium · Severity: Low
  • CAPEC-332 ICMP IP 'ID' Field Error Message Probe Likelihood: Medium · Severity: Low
  • CAPEC-541 Application Fingerprinting Severity: Low
  • CAPEC-580 System Footprinting Likelihood: Low · Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.