cve.bz

CVE-2024-49775 siemens: Heap-based Buffer Overflow

9.3 criticalEPSS 1.5%

Critical (9.3) in siemens. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

Severity

CVSS 4.0

9.3 critical
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2024-12-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-122 Heap-based Buffer Overflow
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-49775 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-49775?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-49775?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-49775 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens Opcenter Execution Foundationbefore V2501.0001
Siemens Opcenter Intelligencebefore V2501.0001
Siemens Opcenter Qualitybefore V2512
Siemens Opcenter RDnLbefore V2410
Siemens SIMATIC PCS neo V4.0all versions
Siemens SIMATIC PCS neo V4.1before V4.1 Update 3
Siemens SIMATIC PCS neo V5.0before V5.0 Update 1
Siemens SINEC NMSall versions
Siemens Totally Integrated Automation Portal (TIA Portal) V16all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V17all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V18all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V19all versions

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-354-04Siemens User Management Component2024-12-16Critical ManufacturingOpcenter Execution Foundation, Opcenter Intelligence, Opcenter Quality and 9 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON