5.5 mediumEPSS 0.2%Fix available

Medium (5.5) in siemens tecnomatix plant simulation. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.

Severity

CVSS 3.1

5.5 medium
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 6th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2024-02-13. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-476 NULL Pointer Dereference
OWASP Top 10
A10:2025 Mishandling of Exceptional Conditions
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2024-23800 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-23800?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-23800?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-23800 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens Tecnomatix Plant Simulation V2201all versions
Siemens Tecnomatix Plant Simulation V2302before V2302.0007

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-046-07Siemens Tecnomatix Plant Simulation2024-02-13MultipleTecnomatix Plant Simulation V2201, Tecnomatix Plant Simulation V2302none listed