cve.bz

CVE-2023-30755 siemens: NULL Pointer Dereference

5.9 mediumEPSS 0.4%

Medium (5.9) in siemens. EPSS 0.4% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system.

Severity

CVSS 4.0

5.9 medium
CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

4.4 medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H
EPSS
0.4% (unchanged from 0.4% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 38th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2024-09-10. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-476 NULL Pointer Dereference
OWASP Top 10
A10:2025 Mishandling of Exceptional Conditions
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2023-30755 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-30755?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-30755?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-30755 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)before V3.5.20
Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants)before V3.5.20
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)before V3.5.20
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)before V3.5.20
Siemens SIMATIC CP 1243-7 LTEbefore V3.5.20
Siemens SIMATIC CP 1243-8 IRCbefore V3.5.20
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants)All versions
Siemens SIMATIC IPC DiagBaseall versions
Siemens SIMATIC IPC DiagMonitorAll versions
Siemens SIMATIC WinCC Runtime AdvancedAll versions
Siemens SIPLUS TIM 1531 IRCbefore V2.4.8
Siemens TIM 1531 IRCbefore V2.4.8

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-256-09Siemens SIMATIC, SIPLUS, and TIM2024-09-10MultipleSIMATIC CP 1242-7 V2 (incl. SIPLUS variants), SIMATIC CP 1243-1 (incl. SIPLUS variants), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) and 9 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References