cve.bz

CVE-2022-34761 schneider-electric: NULL Pointer Dereference

7.5 highEPSS 0.9%Fix available

High (7.5) in schneider-electric. EPSS 0.9% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
0.9% (unchanged from 0.9% a week ago; 0.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 61st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-476 NULL Pointer Dereference
OWASP Top 10
A10:2025 Mishandling of Exceptional Conditions
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2022-34761 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-34761?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-34761?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-34761 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Schneider Electric OPC UA Modicon Communication Modulefrom BMENUA0100 before V1.10
Schneider Electric X80 advanced RTU Communication Modulefrom V2.01 before BMENOR2200H*

References

Check your stackJSON