A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900L, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS969, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
0.6% (unchanged from 0.6% a week ago; 0.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 51st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-208 Observable Timing Discrepancy
CWE-203 Observable Discrepancy
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-42016 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-42016?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-42016?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-42016 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens RUGGEDCOM i800before V4.3.8
Siemens RUGGEDCOM i801before V4.3.8
Siemens RUGGEDCOM i802before V4.3.8
Siemens RUGGEDCOM i803before V4.3.8
Siemens RUGGEDCOM M2100before V4.3.8
Siemens RUGGEDCOM M2100Fall versions
Siemens RUGGEDCOM M2200before V4.3.8
Siemens RUGGEDCOM M2200Fall versions
Siemens RUGGEDCOM M969before V4.3.8
Siemens RUGGEDCOM M969Fall versions
Siemens RUGGEDCOM RMC30before V4.3.8
Siemens RUGGEDCOM RMC8388 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RMC8388 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RP110before V4.3.8
Siemens RUGGEDCOM RS1600before V4.3.8
Siemens RUGGEDCOM RS1600Fbefore V4.3.8
Siemens RUGGEDCOM RS1600Tbefore V4.3.8
Siemens RUGGEDCOM RS400before V4.3.8
Siemens RUGGEDCOM RS400Fall versions
Siemens RUGGEDCOM RS401before V4.3.8
Siemens RUGGEDCOM RS416before V4.3.8
Siemens RUGGEDCOM RS416Fall versions
Siemens RUGGEDCOM RS416Pbefore V4.3.8
Siemens RUGGEDCOM RS416PFall versions
Siemens RUGGEDCOM RS416Pv2 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS416Pv2 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RS416v2 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS416v2 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RS8000before V4.3.8
Siemens RUGGEDCOM RS8000Abefore V4.3.8
Siemens RUGGEDCOM RS8000Hbefore V4.3.8
Siemens RUGGEDCOM RS8000Tbefore V4.3.8
Siemens RUGGEDCOM RS900before V4.3.8
Siemens RUGGEDCOM RS900 (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS900 (32M) V5.Xbefore V5.6.0
Siemens RUGGEDCOM RS900Fall versions
Siemens RUGGEDCOM RS900Gbefore V4.3.8
Siemens RUGGEDCOM RS900G (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS900G (32M) V5.Xbefore V5.6.0
Siemens RUGGEDCOM RS900GFall versions
Siemens RUGGEDCOM RS900GPbefore V4.3.8
Siemens RUGGEDCOM RS900GPFall versions
Siemens RUGGEDCOM RS900Lbefore V4.3.8
Siemens RUGGEDCOM RS900M-GETS-C01before V4.3.8
Siemens RUGGEDCOM RS900M-GETS-XXbefore V4.3.8
Siemens RUGGEDCOM RS900M-STND-C01before V4.3.8
Siemens RUGGEDCOM RS900M-STND-XXbefore V4.3.8
Siemens RUGGEDCOM RS900Wbefore V4.3.8
Siemens RUGGEDCOM RS910before V4.3.8
Siemens RUGGEDCOM RS910Lbefore V4.3.8
Siemens RUGGEDCOM RS910Wbefore V4.3.8
Siemens RUGGEDCOM RS920Lbefore V4.3.8
Siemens RUGGEDCOM RS920Wbefore V4.3.8
Siemens RUGGEDCOM RS930Lbefore V4.3.8
Siemens RUGGEDCOM RS930Wbefore V4.3.8
Siemens RUGGEDCOM RS940Gbefore V4.3.8
Siemens RUGGEDCOM RS940GFall versions
Siemens RUGGEDCOM RS969before V4.3.8
Siemens RUGGEDCOM RSG2100before V4.3.8
Siemens RUGGEDCOM RSG2100 (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2100 (32M) V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2100Fall versions
Siemens RUGGEDCOM RSG2100Pbefore V4.3.8
Siemens RUGGEDCOM RSG2100P (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2100P (32M) V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2100PFall versions
Siemens RUGGEDCOM RSG2200before V4.3.8
Siemens RUGGEDCOM RSG2200Fall versions
Siemens RUGGEDCOM RSG2288 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2288 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2300 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2300 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2300Fall versions
Siemens RUGGEDCOM RSG2300P V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2300P V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2300PFall versions
Siemens RUGGEDCOM RSG2488 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2488 V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSG2488Fall versions
Siemens RUGGEDCOM RSG907Rbefore V5.6.0
Siemens RUGGEDCOM RSG908Cbefore V5.6.0
Siemens RUGGEDCOM RSG909Rbefore V5.6.0
Siemens RUGGEDCOM RSG910Cbefore V5.6.0
Siemens RUGGEDCOM RSG920P V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG920P V5.Xbefore V5.6.0
Siemens RUGGEDCOM RSL910before V5.6.0
Siemens RUGGEDCOM RST2228before V5.6.0
Siemens RUGGEDCOM RST2228Pbefore V5.6.0
Siemens RUGGEDCOM RST916Cbefore V5.6.0
Siemens RUGGEDCOM RST916Pbefore V5.6.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-069-12Siemens RUGGEDCOM ROS2022-03-08Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and FacilitiesRUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802 and 47 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-189 Black Box Reverse Engineering Severity: Low
  • CAPEC-462 Cross-Domain Search Timing Severity: Medium
  • CAPEC-541 Application Fingerprinting Severity: Low
  • CAPEC-580 System Footprinting Likelihood: Low · Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON