Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
3.9% (unchanged from 3.9% a week ago; 3.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 91st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-122 Heap-based Buffer Overflow
CWE-787 Out-of-bounds Write
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-20587 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-20587?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-20587?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-20587 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
mitsubishielectric:cpu_module_logging_configuration_toolthrough 1.112r
mitsubishielectric:cw_configuratorthrough 1.011m
mitsubishielectric:data_transferthrough 3.44w
mitsubishielectric:fr_configurator2through 1.24a
mitsubishielectric:gt_designer3through 1.250l
mitsubishielectric:gt_softgot1000through 3.245f
mitsubishielectric:gt_softgot2000through 1.250l
mitsubishielectric:gx_configurator-dpthrough 7.14q
mitsubishielectric:gx_developerthrough 8.506c
mitsubishielectric:gx_logviewerthrough 1.115u
mitsubishielectric:gx_works2through 1.597x
mitsubishielectric:gx_works3through 1.070y
mitsubishielectric:melfa-worksthrough 4.4
mitsubishielectric:melsoft_navigatorthrough 2.74c
mitsubishielectric:mh11_settingtool_version2through 2.004e
mitsubishielectric:mt_works2through 1.167z
mitsubishielectric:mx_componentthrough 5.001b
mitsubishielectric:px_developerthrough 1.53f
mitsubishielectric:rt_toolbox2through 3.73b
mitsubishielectric:rt_toolbox3through 1.82l
mitsubishielectric:slmp_data_collectorthrough 1.04e

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-049-02Mitsubishi Electric FA Engineering Software Products (Update H)2021-02-18Critical ManufacturingMitsubishi Electric CPU Module Logging Configuration Tool: <=1.112R, Mitsubishi Electric CW Configurator: <=1.011M, Mitsubishi Electric Data Transfer: <=3.44W and 38 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.