cve.bz

CVE-2020-28391 siemens: Use of Hard-coded Cryptographic Key

5.9 mediumEPSS 1.1%

Medium (5.9) in siemens. EPSS 1.1% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.

Severity

CVSS 3.1

5.9 medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
1.1% (unchanged from 1.1% a week ago; 1.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 67th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-321 Use of Hard-coded Cryptographic Key
CWE-798 Use of Hard-coded Credentials
OWASP Top 10
A04:2025 Cryptographic Failures, A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2020-28391 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-28391?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-28391?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-28391 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:scalance_x200-4pirt_firmwarebefore 5.5.0
siemens:scalance_x201-3pirt_firmwarebefore 5.5.0
siemens:scalance_x202-2irt_firmwarebefore 5.5.0
siemens:scalance_x202-2pirt_firmwarebefore 5.5.0
siemens:scalance_x202-2pirt_siplus_net_firmwarebefore 5.5.0
siemens:scalance_x204irt_firmwarebefore 5.5.0
siemens:scalance_xb205-3_firmwarebefore 5.2.5
siemens:scalance_xb205-3ld_firmwarebefore 5.2.5
siemens:scalance_xb208_firmwarebefore 5.2.5
siemens:scalance_xb213-3_firmwarebefore 5.2.5
siemens:scalance_xb213-3ld_firmwarebefore 5.2.5
siemens:scalance_xb216_firmwarebefore 5.2.5
siemens:scalance_xc206-2_firmwarebefore 5.2.5
siemens:scalance_xc206-2g_poe__firmwarebefore 5.2.5
siemens:scalance_xc206-2g_poe_eec_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_eec_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc208_firmwarebefore 5.2.5
siemens:scalance_xc208eec_firmwarebefore 5.2.5
siemens:scalance_xc208g_firmwarebefore 5.2.5
siemens:scalance_xc208g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc208g_eec_firmwarebefore 5.2.5
siemens:scalance_xc208g_poe_firmwarebefore 5.2.5
siemens:scalance_xc216_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc216eec_firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g__firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc224__firmwarebefore 5.2.5
siemens:scalance_xf201-3p_irt_firmwarebefore 5.2.5
siemens:scalance_xf202-2p_irt_firmwarebefore 5.2.5
siemens:scalance_xf204_firmwarebefore 5.2.5
siemens:scalance_xf204-2_firmwarebefore 5.2.5
siemens:scalance_xf204-2ba_dna_firmwarebefore 5.2.5
siemens:scalance_xf204-2ba_irt_firmwarebefore 5.2.5
siemens:scalance_xf204_dna_firmwarebefore 5.2.5
siemens:scalance_xf204irt_firmwarebefore 5.2.5
siemens:scalance_xf206-1_firmwarebefore 5.2.5
siemens:scalance_xf208_firmwarebefore 5.2.5
siemens:scalance_xp208_firmwarebefore 5.2.5
siemens:scalance_xp208_(eip)_firmwarebefore 5.2.5
siemens:scalance_xp208eec_firmwarebefore 5.2.5
siemens:scalance_xp208poe_eec_firmwarebefore 5.2.5
siemens:scalance_xp216_firmwarebefore 5.2.5
siemens:scalance_xp216_(eip)_firmwarebefore 5.2.5
siemens:scalance_xp216eec_firmwarebefore 5.2.5
siemens:scalance_xp216poe_eec_firmwarebefore 5.2.5

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-012-02Siemens SCALANCE X Switches (Update B)2021-01-12MultipleSCALANCE X-200 switch family (incl. SIPLUS NET variants), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SCALANCE X-200RNA switch familynone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-70 Try Common or Default Usernames and Passwords Likelihood: Medium · Severity: High
  • CAPEC-191 Read Sensitive Constants Within an Executable Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.