cve.bz

CVE-2019-8262 Out-of-bounds Write

9.8 criticalEPSS 4.8%

Critical (9.8). EPSS 4.8% estimated probability of exploitation activity in the next 30 days.

On this page
UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
4.8% (unchanged from 4.8% a week ago; 4.8% 30 days ago) estimated probability of exploitation activity in the next 30 days; 92nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-787 Out-of-bounds Write
CWE-122 Heap-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2019-8262 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-8262?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-8262?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-8262 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

  • siemens:sinumerik_access_mymachine\/p2p
  • siemens:sinumerik_pcu_base_win10_software\/ipc
  • siemens:sinumerik_pcu_base_win7_software\/ipc
  • uvnc:ultravnc

Versions

From the NVD's CPE matches.

ProductAffected
uvnc:ultravncbefore 1.2.2.3
siemens:sinumerik_access_mymachine/p2pbefore 4.8
siemens:sinumerik_pcu_base_win10_software/ipcbefore 14.00
siemens:sinumerik_pcu_base_win7_software/ipcthrough 12.01

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-131-04Siemens SINAMICS Medium Voltage Products Remote Access (Update B)2021-05-11MultipleSINAMICS GH150, SINAMICS GL150 (with option X30), SINAMICS GM150 (with option X30) and 5 morenone listed
ICSA-21-131-11Siemens SIMATIC UltraVNC HMI WinCC Products2021-05-11MultipleSIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F and 1 morenone listed
ICSA-20-161-06Siemens SINUMERIK2020-06-09MultipleSiemens SINUMERIK Access MyMachine /P2P: All versions < V4.8, Siemens SINUMERIK PCU base Win10 software /IPC: All versions < V14.00, Siemens SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON