cve.bz

CVE-2019-8258 Out-of-bounds Write

9.8 criticalEPSS 4.4%

Critical (9.8). EPSS 4.4% estimated probability of exploitation activity in the next 30 days.

On this page
UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
4.4% (unchanged from 4.4% a week ago; 4.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 92nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-787 Out-of-bounds Write
CWE-122 Heap-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2019-8258 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-8258?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-8258?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-8258 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

  • siemens:sinumerik_access_mymachine\/p2p
  • siemens:sinumerik_pcu_base_win10_software\/ipc
  • siemens:sinumerik_pcu_base_win7_software\/ipc
  • uvnc:ultravnc

Versions

From the NVD's CPE matches.

ProductAffected
uvnc:ultravncbefore 1.2.2.3
siemens:sinumerik_access_mymachine/p2pbefore 4.8
siemens:sinumerik_pcu_base_win10_software/ipcbefore 14.00
siemens:sinumerik_pcu_base_win7_software/ipcthrough 12.01

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-20-161-06Siemens SINUMERIK2020-06-09MultipleSiemens SINUMERIK Access MyMachine /P2P: All versions < V4.8, Siemens SINUMERIK PCU base Win10 software /IPC: All versions < V14.00, Siemens SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON