cve.bz

CVE-2018-14821 rockwellautomation rslinx: Heap-based Buffer Overflow

7.5 highExploit referenceEPSS 4.5%

High (7.5) in rockwellautomation rslinx. EPSS 4.5% estimated probability of exploitation activity in the next 30 days.

On this page
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.

Severity

CVSS 3.0

7.5 high
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
4.5% (unchanged from 4.5% a week ago; 4.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 92nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE-122 Heap-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2018-14821 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2018-14821?via=ask-ai-copy and https://cve.bz/cve/CVE-2018-14821?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2018-14821 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
rockwellautomation:rslinxthrough 4.00.01

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-18-263-02Rockwell Automation RSLinx Classic2018-09-20Critical Manufacturing, Energy, Water and Wastewater SystemsRSLinx Classic: Versions 4.00.01 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).

References

Check your stackJSON