cve.bz

CVE-2018-11457 siemens: Heap-based Buffer Overflow

8.1 highEPSS 4.6%

High (8.1) in siemens. EPSS 4.6% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Severity

CVSS 3.0

8.1 high
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
4.6% (unchanged from 4.6% a week ago; 4.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 92nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-122 Heap-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2018-11457 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2018-11457?via=ask-ai-copy and https://cve.bz/cve/CVE-2018-11457?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2018-11457 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:sinumerik_828d_v4.7_firmwarethrough 4.7
siemens:sinumerik_840d_sl_v4.7_firmwarethrough 4.7
siemens:sinumerik_840d_sl_v4.8_firmwarethrough 4.8

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-18-345-02ICSA-18-345-02 Siemens SINUMERIK Controllers (Update A)2018-12-11MultipleSINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7 and 2 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-92 Forced Integer Overflow Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON