tenda vulnerabilities, newest first, page 16
Filter
By year: all 2026 2025 2024 2023 2022 2021
- 6.9CVE-2025-3237EPSS 0.6%
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiat…
- 6.9CVE-2025-3236EPSS 0.7%
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/VirSerDMZ of the component Web Management Interface. The manipulation leads to improper …
- 5.3CVE-2025-3203EPSS 0.6%
A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based …
- 9.8CVE-2025-29462EPSS 0.6%
A buffer overflow vulnerability has been discovered in Tenda Ac15 V15.13.07.13. The vulnerability occurs when the webCgiGetUploadFile function calls the socketRead function to process HTTP request messages, resulting in the overwriting of …
- 7.1CVE-2025-3167EPSS 0.9%
A vulnerability, which was classified as problematic, has been found in Tenda AC23 16.03.07.52. This issue affects some unknown processing of the file /goform/VerAPIMant of the component API Interface. The manipulation of the argument getu…
- 8.7CVE-2025-3161EPSS 0.9%
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. …
- 6.9CVE-2025-2996EPSS 0.8%
A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. This issue affects some unknown processing of the file /goform/SysToolDDNS of the component Web Management Interface. The manipulation leads to improper ac…
- 6.9CVE-2025-2995EPSS 0.8%
A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects unknown code of the file /goform/SysToolChangePwd of the component Web Management Interface. The manipulation leads to impr…
- 6.9CVE-2025-2994EPSS 0.7%
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects an unknown part of the file /goform/qossetting of the component Web Management Interface. The manipulation leads to improper access co…
- 6.9CVE-2025-2993EPSS 11%
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is some unknown functionality of the file /default.cfg. The manipulation of the argument these leads to improper access…
- 6.9CVE-2025-2992EPSS 0.7%
A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is an unknown functionality of the file /goform/AdvSetWrlsafeset of the component Web Management Interface. The manipulation lea…
- 6.9CVE-2025-2991EPSS 0.7%
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is an unknown function of the file /goform/AdvSetWrlmacfilter of the component Web Management Interface. The manipulation leads to improper acces…
- 6.9CVE-2025-2990EPSS 0.7%
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/AdvSetWrlGstset of the component Web Management Interface. The manipulation leads to imp…
- 6.9CVE-2025-2989EPSS 0.7%
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/AdvSetWrl of the component Web Management Interface. The manipulation leads to improper …
- 7.5CVE-2025-28221EPSS 0.5%
Tenda W6_S v1.0.0.4_510 has a Buffer Overflow vulnerability in the set_local_time function, which allows remote attackers to cause web server crash via parameter time passed to the binary through a POST request.
- 7.5CVE-2025-28220EPSS 0.5%
Tenda W6_S v1.0.0.4_510 has a Buffer Overflow vulnerability in the setcfm function, which allows remote attackers to cause web server crash via parameter funcpara1 passed to the binary through a POST request.
- 9.8CVE-2025-29135EPSS 1.1%
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.
- 9.8CVE-2025-29100EPSS 0.6%
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
- 6.5CVE-2025-29218EPSS 0.5%
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
- 6.5CVE-2025-29217EPSS 0.5%
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
- 6.5CVE-2025-29215EPSS 0.8%
Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_43fdcc function at /goform/SetNetControlList.
- 7.5CVE-2025-29149EPSS 0.5%
Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function.
- 7.5CVE-2025-29121EPSS 0.5%
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
- 7.5CVE-2025-29214EPSS 0.6%
Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_42F69C function at /goform/setMacFilterCfg.
- 7.5CVE-2025-29101EPSS 0.5%
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
- 6.5CVE-2025-29118EPSS 0.3%
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
- 9.8CVE-2025-29137EPSS 0.6%
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE.
- 7.1CVE-2025-29387EPSS 0.6%
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
- 9.8CVE-2025-29386EPSS 0.9%
In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
- 9.8CVE-2025-29385EPSS 0.9%
In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
- 9.8CVE-2025-29384EPSS 1.9%
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
- 9.8CVE-2025-29031EPSS 0.5%
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function.
- 9.8CVE-2025-29030EPSS 0.5%
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function.
- 9.8CVE-2025-29029EPSS 0.5%
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function.
- 7.5CVE-2025-29363EPSS 0.5%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) vi…
- 7.5CVE-2025-29362EPSS 0.5%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/setPptpUserList. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 7.5CVE-2025-29361EPSS 0.8%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/SetVirtualServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 7.5CVE-2025-29360EPSS 0.5%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 7.5CVE-2025-29359EPSS 0.5%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 7.5CVE-2025-29358EPSS 0.8%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 7.5CVE-2025-29357EPSS 0.5%
Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet.
- 6.5CVE-2025-25634EPSS 0.3%
A vulnerability has been found in Tenda AC15 15.03.05.19 in the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src leads to stack-based buffer overflow.
- 9.8CVE-2025-25632EPSS 1.7%
Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet.
- 7.1CVE-2025-1899EPSS 0.7%
A vulnerability has been found in Tenda TX3 16.03.13.11_multi and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer…
- 7.1CVE-2025-1898EPSS 0.9%
A vulnerability, which was classified as critical, was found in Tenda TX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to buffer ov…
- 7.1CVE-2025-1897EPSS 1.2%
A vulnerability, which was classified as critical, has been found in Tenda TX3 16.03.13.11_multi. This issue affects some unknown processing of the file /goform/SetNetControlList. The manipulation of the argument list leads to buffer overf…
- 7.1CVE-2025-1896EPSS 0.9%
A vulnerability classified as critical was found in Tenda TX3 16.03.13.11_multi. This vulnerability affects unknown code of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to buffer overflow. The attack can …
- 7.1CVE-2025-1895EPSS 0.9%
A vulnerability classified as critical has been found in Tenda TX3 16.03.13.11_multi. This affects an unknown part of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to buffer overflow. It is possible to…
- 8.7CVE-2025-1853EPSS 1.5%
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to s…
- 8.7CVE-2025-1851EPSS 1.1%
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based …