cve.bz

tenda ac18 firmware vulnerabilities, newest first

Filter

By year: all 2026 2025 2024 2023 2022 2021

  1. 9.8CVE-2026-31255EPSS 1.1%

    A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system c…

  2. 7.4CVE-2025-14993EPSS 0.7%

    A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflo…

  3. 7.4CVE-2025-14992EPSS 0.7%

    A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to…

  4. 8.8CVE-2025-63835EPSS 0.7%

    A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by send…

  5. 5.4CVE-2025-63834EPSS 0.2%

    A stored cross-site scripting (XSS) vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the ssid parameter of the wireless settings. Remote attackers can inject malicious payloads that execute when an…

  6. 7.4CVE-2025-11328EPSS 1.1%

    A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to laun…

  7. 7.4CVE-2025-11327EPSS 1.3%

    A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possibl…

  8. 7.4CVE-2025-11326EPSS 1.3%

    A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may …

  9. 7.4CVE-2025-11325EPSS 0.8%

    A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based…

  10. 7.4CVE-2025-11324EPSS 0.8%

    A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow…

  11. 7.5CVE-2025-60663EPSS 0.4%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanMTU parameter in the fromAdvSetMacMtuWan function.

  12. 5.3CVE-2025-60661EPSS 0.4%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the cloneType parameter in the fromAdvSetMacMtuWan function.

  13. 7.5CVE-2025-60662EPSS 0.5%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanSpeed parameter in the fromAdvSetMacMtuWan function.

  14. 7.5CVE-2025-60660EPSS 0.5%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the mac parameter in the fromAdvSetMacMtuWan function.

  15. 7.4CVE-2025-11123EPSS 0.9%

    A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The explo…

  16. 7.4CVE-2025-11122EPSS 0.9%

    A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched re…

  17. 2.1CVE-2025-11121EPSS 3.5%

    A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiat…

  18. 7.4CVE-2025-11120EPSS 4.0%

    A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack …

  19. 7.4CVE-2025-9023EPSS 0.9%

    A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch …

  20. 2.9CVE-2025-8182EPSS 0.5%

    A vulnerability has been found in Tenda AC18 15.03.05.19 and classified as problematic. This vulnerability affects unknown code of the file /etc_ro/smb.conf of the component Samba. The manipulation leads to weak password requirements. The …

  21. 8.7CVE-2025-5609EPSS 1.1%

    A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. …

  22. 8.7CVE-2025-5608EPSS 1.1%

    A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It …

  23. 8.7CVE-2025-5607EPSS 1.1%

    A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. Th…

  24. 5.3CVE-2025-5606EPSS 3.8%

    A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. Th…

  25. 8.6CVE-2025-0528EPSS 6.2%

    A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulat…

  26. 9.8CVE-2024-57583EPSS 1.6%

    Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function.

  27. 9.8CVE-2024-57582EPSS 0.8%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function.

  28. 9.8CVE-2024-57581EPSS 0.8%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.

  29. 9.8CVE-2024-57580EPSS 0.8%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.

  30. 9.8CVE-2024-57579EPSS 0.7%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.

  31. 8.8CVE-2024-57578EPSS 0.6%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function.

  32. 5.7CVE-2024-57577EPSS 0.3%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.

  33. 9.8CVE-2024-57575EPSS 0.8%

    Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.

  34. 7.1CVE-2024-10280EPSS 0.8%

    A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation …

  35. 7.6CVE-2024-41630EPSS 1.0%

    Stack-based buffer overflow vulnerability in Tenda AC18 V15.03.3.10_EN allows a remote attacker to execute arbitrary code via the ssid parameter at ip/goform/fast_setting_wifi_set.

  36. 8.8CVE-2024-33181EPSS 0.6%

    Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter.

  37. 8.2CVE-2024-34974EPSS 0.7%

    Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter.

  38. 9.8CVE-2024-33835EPSS 0.8%

    Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.

  39. 8.8CVE-2024-30891EPSS 1.9%

    A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.

  40. 7.5CVE-2024-28551EPSS 0.8%

    Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the ssid parameter of form_fast_setting_wifi_set function.

  41. 9.8CVE-2024-28545EPSS 2.3%

    Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.

  42. 9.8CVE-2024-2854EPSS 3.9%

    A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possi…

  43. 6.5CVE-2024-28547EPSS 0.5%

    Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.

  44. 9.8CVE-2024-28537EPSS 0.8%

    Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.

  45. 4.3CVE-2024-28550EPSS 0.4%

    Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.

  46. 4.3CVE-2024-2560EPSS 0.4%

    A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery…

  47. 6.5CVE-2024-2559EPSS 0.3%

    A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launc…

  48. 8.8CVE-2024-2558EPSS 1.3%

    A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overf…

  49. 8.8CVE-2024-2547EPSS 1.2%

    A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be…

  50. 8.8CVE-2024-2546EPSS 1.0%

    A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflo…