- 4.6CVE-2026-1763EPSS 0.2%
Vulnerability in GE Vernova Enervista UR Setup on Windows.This issue affects Enervista: 8.6 and previous versions.
- 2.9CVE-2026-1762EPSS 0.3%
A vulnerability in GE Vernova Enervista UR Setup on Windows allows File Manipulation.This issue affects Enervista: 8.6 and prior versions.
- 5.3CVE-2025-7719EPSS 0.4%
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in GE Vernova Smallworld on Windows, Linux allows File Manipulation.This issue affects Smallworld: 5.3.5. and previous versions.
- 9.3CVE-2025-3222EPSS 0.4%
Improper Authentication vulnerability in GE Vernova Smallworld on Windows, Linux allows Authentication Abuse.This issue affects Smallworld: 5.3.3 and prior versions for Linux, and 5.3.4. and prior versions for Windows.
- 7.5CVE-2025-9038EPSS 0.1%
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version.
- 5.9CVE-2025-3223EPSS 0.2%
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in GE Vernova WorkstationST on Windows (EGD Configuration Server modules) allows Path Traversal.This issue affects WorkstationST: WorkstationST V0…
- 6.1CVE-2025-27257EPSS 0.2%
Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware. The firmware signature verification is enforced only on the client-side dedicated…
- 8.3CVE-2025-27256EPSS 0.3%
Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker …
- 8.0CVE-2025-27255EPSS 0.2%
Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code.
- 8.0CVE-2025-27254EPSS 0.2%
CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass. The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify.
- 6.1CVE-2025-27253EPSS 0.2%
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the…