cognex vulnerabilities, newest first
Filter
By year: all 2026 2025 2024 2023 2022 2021
- 6.9CVE-2025-54860EPSS 0.1%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow management operations on the device such as firmware upgrades and device reboot requiring an authentication. A wrong managem…
- 8.6CVE-2025-54818EPSS 0.1%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as…
- 8.6CVE-2025-54810EPSS 0.2%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as…
- 7.2CVE-2025-54497EPSS 0.3%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges …
- 8.6CVE-2025-53969EPSS 0.4%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a service implementing a proprietary protocol on TCP port 1069 to allow the client-side software, such as the In-Sight Explorer tool, to perform management operations such as …
- 7.2CVE-2025-52873EPSS 0.3%
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges c…
- 8.6CVE-2025-54754EPSS 0.3%
An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, aff…
- 6.9CVE-2025-53947EPSS 0.1%
A local attacker with low privileges on the Windows system where the software is installed can exploit this vulnerability to corrupt sensitive data. A data folder is created with very weak privileges, allowing any user logged into the W…
- 8.6CVE-2025-47698EPSS 0.1%
An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.
- 9.1CVE-2022-1525EPSS 0.9%
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modif…
- 5.3CVE-2022-1522EPSS 0.6%
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been chang…
- 9.8CVE-2022-1368EPSS 1.0%
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserve…
- 9.8CVE-2021-32935EPSS 1.9%
The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation.