- 7.8CVE-2022-2006EPSS 0.4%
AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-…
- 7.5CVE-2022-2005EPSS 0.6%
AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: Automation…
- 7.5CVE-2022-2004EPSS 1.1%
AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect…
- 9.1CVE-2022-2003EPSS 0.8%
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized …
- 9.8CVE-2021-32986EPSS 1.1%
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subseq…
- 9.8CVE-2021-32984EPSS 1.1%
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized use…
- 7.5CVE-2021-32982EPSS 0.7%
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange.
- 9.8CVE-2021-32980EPSS 1.1%
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.
- 7.5CVE-2021-32978EPSS 1.0%
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU…
- 7.5CVE-2020-10922EPSS 3.7%
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The spe…
- 9.8CVE-2020-10921EPSS 2.8%
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists with…
- 9.8CVE-2020-10920EPSS 4.9%
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exi…
- 5.9CVE-2020-10919EPSS 1.6%
This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific …
- 7.5CVE-2020-10918EPSS 2.7%
This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exis…
- 9.8CVE-2020-6969EPSS 2.4%
It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system c…
- 7.8CVE-2017-14020EPSS 1.1%
In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; D…