cve.bz

airspan vulnerabilities, newest first

Filter

By year: all 2026 2025 2024 2023 2022 2021

Includes CVEs the NVD has not named yet, filed by their publishers under: airspan networks.

  1. 8.8CVE-2022-36312EPSS 0.3%

    Airspan AirVelocity 1500 software version 15.18.00.2511 lacks CSRF protections in the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.

  2. 6.1CVE-2022-36311EPSS 0.5%

    Airspan AirVelocity 1500 prior to software version 15.18.00.2511 is vulnerable to injection leading to XSS in the SNMP community field in the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.

  3. 8.8CVE-2022-36310EPSS 1.6%

    Airspan AirVelocity 1500 software prior to version 15.18.00.2511 had NET-SNMP-EXTEND-MIB enabled on its snmpd service, enabling an attacker with SNMP write abilities to execute commands as root on the eNodeB. This issue may affect other Ai…

  4. 8.8CVE-2022-36309EPSS 25%

    Airspan AirVelocity 1500 software versions prior to 15.18.00.2511 have a root command injection vulnerability in the ActiveBank parameter of the recoverySubmit.cgi script running on the eNodeB's web management UI. This issue may affect oth…

  5. 9.1CVE-2022-36308EPSS 0.8%

    Airspan AirVelocity 1500 web management UI displays SNMP credentials in plaintext on software versions older than 15.18.00.2511, and stores SNMPv3 credentials unhashed on the filesystem, enabling anyone with web access to use these credent…

  6. 6.8CVE-2022-36307EPSS 0.3%

    The AirVelocity 1500 prints SNMP credentials on its physically accessible serial port during boot. This was fixed in AirVelocity 1500 software version 15.18.00.2511 and may affect other AirVelocity and AirSpeed models.

  7. 6.5CVE-2022-36306EPSS 1.0%

    An authenticated attacker can enumerate and download sensitive files, including the eNodeB's web management UI's TLS private key, the web server binary, and the web server configuration file. These vulnerabilities were found in AirVelocity…

  8. 9.8CVE-2022-36267ExploitEPSS 54%

    In Airspan AirSpot 5410 version 0.3.4.1-4 and under there exists a Unauthenticated remote command injection vulnerability. The ping functionality can be called without user authentication when crafting a malicious http request by injecting…

  9. 6.1CVE-2022-36266EPSS 1.1%

    In Airspan AirSpot 5410 version 0.3.4.1-4 and under there exists a stored XSS vulnerability. As the binary file /home/www/cgi-bin/login.cgi does not check if the user is authenticated, a malicious actor can craft a specific request on the …

  10. 7.2CVE-2022-36265EPSS 1.5%

    In Airspan AirSpot 5410 version 0.3.4.1-4 and under there exists a Hidden system command web page. After performing a reverse engineering of the firmware, it was discovered that a hidden page not listed in the administration management int…

  11. 9.1CVE-2022-36264EPSS 1.7%

    In Airspan AirSpot 5410 version 0.3.4.1-4 and under there exists an Unauthenticated remote Arbitrary File Upload vulnerability which allows overwriting arbitrary files. A malicious actor can remotely upload a file of their choice and overw…

  12. 6.5CVE-2022-21800EPSS 0.5%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. A…

  13. 9.8CVE-2022-21215EPSS 1.4%

    This vulnerability could allow an attacker to force the server to create and execute a web request granting access to backend APIs that are only accessible to the Mimosa MMP server, or request pages that could perform some actions themselv…

  14. 9.8CVE-2022-21196EPSS 3.7%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not perform proper authorization and authentication checks on multiple API routes. An att…

  15. 7.5CVE-2022-21176EPSS 1.1%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not properly sanitize user input, which may allow an attacker to perform a SQL injection …

  16. 9.8CVE-2022-21143EPSS 1.2%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not properly sanitize user input on several locations, which may allow an attacker to inj…

  17. 9.8CVE-2022-21141EPSS 3.2%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not perform proper authorization checks on multiple API functions. An attacker may gain a…

  18. 7.5CVE-2022-0138EPSS 1.0%

    MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 has a deserialization function that does not validate or check the data, allowing arbitrary cl…

  19. –CVE-2008-1543EPSS 1.2%

    The Advanced User Interface Pages in the ProST Web Management component on the Airspan WiMAX ProST have a certain default User ID and password, which makes it easier for remote attackers to obtain partial administrative access, a different…

  20. –CVE-2008-1542EPSS 1.8%

    Airspan Base Station Distribution Unit (BSDU) has "topsecret" as its password for the root account, which allows remote attackers to obtain administrative access via a telnet login, a different vulnerability than CVE-2008-1262.

  21. –CVE-2008-1262ExploitEPSS 8.5%

    The administration panel on the Airspan WiMax ProST 4.1 antenna with 6.5.38.0 software does not verify authentication credentials, which allows remote attackers to (1) upload malformed firmware or (2) bind the antenna to a different WiMAX …