CWE-477: Use of Obsolete Function
Filter
The code uses deprecated or obsolete functions, which suggests that the code has not been actively reviewed or maintained.
What the weakness is: CWE-477 at MITRE. OWASP Top 10: A03:2025 Software Supply Chain Failures. All weaknesses
Ask an AI about CWE-477
Show the prompt
Explain CWE-477: Use of Obsolete Function and how to prevent and detect it in code. Use https://cwe.mitre.org/data/definitions/477.html and https://cve.bz/cve/cwe/477?via=ask-ai-copy for recent CVEs with this weakness. Cite the sources.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this weakness's id and public links.
- 5.3CVE-2026-1693EPSS 0.4%
The OAuth grant type Resource Owner Password Credentials (ROPC) flow is still used by the werbservices used by the WebVue, WebScheduler, TouchVue and Snapvue features of PcVue in version 12.0.0 through 16.3.3 included despite being depreca…
- 9.8CVE-2025-49217EPSS 1.1%
An insecure deserialization operation in the Trend Micro Endpoint Encryption PolicyServer could lead to a pre-authentication remote code execution on affected installations. Note that this vulnerability is similar to CVE-2025-49213 but is …
- 9.8CVE-2025-49216EPSS 0.5%
An authentication bypass vulnerability in the Trend Micro Endpoint Encryption PolicyServer could allow an attacker to access key methods as an admin user and modify product configurations on affected installations.
- 8.8CVE-2025-49214EPSS 0.9%
An insecure deserialization operation in the Trend Micro Endpoint Encryption PolicyServer could lead to a post-authentication remote code execution on affected installations. Please note: an attacker must first obtain the ability to exe…
- 9.8CVE-2025-49213EPSS 13%
An insecure deserialization operation in the Trend Micro Endpoint Encryption PolicyServer could lead to a pre-authentication remote code execution on affected installations. Note that this vulnerability is similar to CVE-2025-49212 but is …
- 9.8CVE-2025-49212EPSS 13%
An insecure deserialization operation in the Trend Micro Endpoint Encryption PolicyServer could lead to a pre-authentication remote code execution on affected installations. Note that this vulnerability is similar to CVE-2025-49220 but is …
- 9.8CVE-2025-49220EPSS 2.1%
An insecure deserialization operation in Trend Micro Apex Central below version 8.0.7007 could lead to a pre-authentication remote code execution on affected installations. Note that this vulnerability is similar to CVE-2025-49219 but is i…
- 9.8CVE-2025-49219EPSS 1.4%
An insecure deserialization operation in Trend Micro Apex Central below versions 8.0.7007 could lead to a pre-authentication remote code execution on affected installations. Note that this vulnerability is similar to CVE-2025-49220 but is …
- 8.8CVE-2023-28829EPSS 0.3%
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC…
- 9.8CVE-2023-23451EPSS 0.6%
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04…
- 8.8CVE-2022-1384EPSS 0.7%
Mattermost version 6.4.x and earlier fails to properly check the plugin version when a plugin is installed from the Marketplace, which allows an authenticated and an authorized user to install and exploit an old plugin version from the Mar…
- 7.2CVE-2020-6978EPSS 0.8%
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries.
- 8.8CVE-2019-18251EPSS 1.7%
In Omron CX-Supervisor, Versions 3.5 (12) and prior, Omron CX-Supervisor ships with Teamviewer Version 5.0.8703 QS. This version of Teamviewer is vulnerable to an obsolete function vulnerability requiring user interaction to exploit.
- 3.4CVE-2019-10988EPSS 0.3%
In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated …
- 4.4CVE-2019-10968EPSS 0.3%
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
- 9.8CVE-2018-17890EPSS 3.3%
NUUO CMS all versions 3.1 and prior, The application uses insecure and outdated software components for functionality, which could allow arbitrary code execution.