CVE-2026-95822 Out-of-bounds read and kernel stack disclosure in the SOCKS5 client when the destination address family differs from the proxy address family
The SOCKS5 client in subsys/net/lib/socks/socks.c built the CONNECT request in socks5_tcp_connect() by choosing the SOCKS5 address type from the address family of the proxy (proxy->sa_family) while reading the bytes out of the destination address supplied to connect(). A SOCKS5 request encodes the destination independently of the transport used to reach the proxy, so the two families are unrelated and nothing in the path forces them to agree: set_context_proxy() only requires the proxy family to match the socket, and zsock_connect_ctx() enters the SOCKS branch before any destination validation. With an IPv6 proxy and an AF_INET destination the code treated an 8-byte struct net_sockaddr_in as a struct net_sockaddr_in6 and copied the 16-byte sin6_addr from it, reading 12 bytes past the end of the object and transmitting them to the proxy.
With CONFIG_USERSPACE enabled, z_vrfy_zsock_connect() copies only addrlen user bytes into a stack-resident struct net_sockaddr_storage and enforces no per-family minimum length, so the oversized read stays within the storage but returns stale, uninitialised kernel-stack bytes. An unprivileged user-mode thread can therefore open an AF_INET6 stream socket, point setsockopt(SO_SOCKS5) at a proxy it controls, and call connect() with a short AF_INET destination to have the kernel send it 12 bytes of supervisor stack residue per attempt. Without CONFIG_USERSPACE the read runs past the end of the caller's own struct net_sockaddr_in, disclosing adjacent memory to the proxy; the family mismatch can arise unintentionally when a destination is obtained from DNS while an IPv6 proxy is configured.
Impact is limited to information disclosure of at most 12 bytes per connect() call, with no write primitive; the leak is delivered to whoever operates the SOCKS5 proxy. The mirrored pairing (IPv6 destination through an IPv4 proxy) is memory-safe but encoded the destination as SOCKS5_ATYP_IPV4 from the first four bytes of the IPv6 address, causing the proxy to connect to an unrelated host. Exploitation requires the non-default CONFIG_SOCKS option, a socket with SO_SOCKS5 configured, and both IPv4 and IPv6 support in the image.
The fix moves the encoding into a helper that selects the address type from dest->sa_family and validates dest_len against the matching struct net_sockaddr_in/struct net_sockaddr_in6 before copying, rejecting under-length or unsupported destinations with an error.
Severity
CVSS 3.1
3.3 low
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2026-11-17. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
Show the promptExplain CVE-2026-95822 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-95822?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-95822?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-95822 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.
Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.