cve.bz

CVE-2026-8045 schneider-electric struxureware data center expert

7.1 highEPSS 0.2%

High (7.1) in schneider-electric struxureware data center expert. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.

Severity

CVSS 4.0

7.1 high
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS 3.1

6.5 medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 14th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2026-06-09. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-611 Improper Restriction of XML External Entity Reference
OWASP Top 10
A02:2025 Security Misconfiguration
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2026-8045 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-8045?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-8045?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-8045 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:struxureware_data_center_expertbefore 9.1.2

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-26-181-03Schneider Electric EcoStruxure IT Data Center Expert2026-06-09Information Technology, Critical Manufacturing, EnergyEcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Version 9.1.1 and PriorEcoStruxure IT Data Center Expert Version 9.1.2

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-221 Data Serialization External Entities Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.