CVE-2026-63248
In Eclipse Milo versions 0.6.0 through 1.1.4, OPC UA server diagnostics nodes do not enforce access authorization. An anonymous client can enable diagnostics over a None/None endpoint without a certificate; with a trusted client application certificate over SignAndEncrypt, it can read security diagnostics for other active sessions, exposing usernames, login history, authentication mechanisms, security modes and policies, and public client certificates.
- CVSS 4.0
- 6.9
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N - CVSS 3.1
- 6.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N - EPSS
- 0.3% chance of exploitation in the next 30 days; higher than 17% of CVEs (scores of 2026-10-25)
- CWE
- CWE-862
- Published
- Modified
- Record from
- the NVD, synced
Affected
- eclipse:milo