cve.bz

CVE-2026-27755 sodola-network sl902-swtgw124as firmware: Use of Insufficiently Random Values

9.3 criticalEPSS 0.5%

Critical (9.3) in sodola-network sl902-swtgw124as firmware. EPSS 0.5% estimated probability of exploitation activity in the next 30 days.

On this page
SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a weak session identifier generation vulnerability that allows attackers to forge authenticated sessions by computing predictable MD5-based cookies. Attackers who know or guess valid credentials can calculate the session identifier offline and bypass authentication without completing the login flow, gaining unauthorized access to the device.

Severity

CVSS 4.0

9.3 critical
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.5% (unchanged from 0.5% a week ago; 0.7% 30 days ago) estimated probability of exploitation activity in the next 30 days; 40th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2026-02-27. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-330 Use of Insufficiently Random Values
OWASP Top 10
A04:2025 Cryptographic Failures
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-27755 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-27755?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-27755?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-27755 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks) SODOLA SL902-SWTGW124ASthrough 200.1.20

Attack patterns (CAPEC)

  • CAPEC-59 Session Credential Falsification through Prediction Likelihood: High · Severity: High
  • CAPEC-112 Brute Force Severity: High
  • CAPEC-485 Signature Spoofing by Key Recreation Likelihood: Low · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON