CVE-2026-24441 tenda ac7 firmware

8.2 highEPSS 0.3%

High (8.2) in tenda ac7 firmware. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.

Severity

CVSS 4.0

8.2 high
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS 3.1

5.9 medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
0.3% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 16th percentile. Scored 2026-11-25. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2026-02-03. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-319 Cleartext Transmission of Sensitive Information
OWASP Top 10
A04:2025 Cryptographic Failures
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-24441 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-24441?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-24441?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-24441 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Shenzhen Tenda Technology Co., Ltd. Tenda AC7through 03.03.03.01_cn

Attack patterns (CAPEC)

  • CAPEC-65 Sniff Application Code Likelihood: Low · Severity: High
  • CAPEC-102 Session Sidejacking Likelihood: High · Severity: High
  • CAPEC-117 Interception Likelihood: Low · Severity: Medium
  • CAPEC-383 Harvesting Information via API Event Monitoring Severity: Low
  • CAPEC-477 Signature Spoofing by Mixing Signed and Unsigned Content Likelihood: Low · Severity: High