cve.bz

CVE-2026-2400 schneider-electric powerchute serial shutdown: CRLF Injection

5.3 mediumEPSS 0.2%

Medium (5.3) in schneider-electric powerchute serial shutdown. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.

Severity

CVSS 4.0

5.3 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N

CVSS 3.1

4.3 medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 14th percentile. Scored 2026-11-16. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2026-04-14. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-93 Improper Neutralization of CRLF Sequences (CRLF Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2026-2400 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-2400?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-2400?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-2400 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:powerchute_serial_shutdownbefore 1.5

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-26-190-02Schneider Electric PowerChute Serial Shutdown2026-04-14Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Information Technology, Transportation SystemsPowerChute™ Serial Shutdown Versions 1.4 and priorPowerChute™ Serial Shutdown Version 1.5 installed on Microsoft Windows, PowerChute™ Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux, PowerChute™ Serial Shutdown Version 1.5 installed on SuSE Linux

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-81 Web Server Logs Tampering Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON