CVE-2026-18267 kenwood dnr1007xr: Link Following

6.8 mediumEPSS 0.4%

Medium (6.8) in kenwood dnr1007xr. EPSS 0.4% estimated probability of exploitation activity in the next 30 days.

On this page
Kenwood DNR1007XR Firmware Update Link Following Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Kenwood DNR1007XR devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware update process. By creating a symbolic link, an attacker can abuse the service to move a file to an arbitrary location. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28751.

Severity

CVSS 3.0

6.8 medium
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.4% (unchanged from 0.4% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 37th percentile. Scored 2026-11-17. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2026-08-26. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-59 Improper Link Resolution Before File Access (Link Following)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-18267 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-18267?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-18267?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-18267 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Kenwood DNR1007XR1.7.0003.1000

Attack patterns (CAPEC)

  • CAPEC-17 Using Malicious Files Likelihood: High · Severity: Very High
  • CAPEC-35 Leverage Executable Code in Non-Executable Files Likelihood: High · Severity: Very High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-132 Symlink Attack Likelihood: Low · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON