cve.bz

CVE-2026-1687 tenda hg10 firmware: Injection

5.5 mediumExploit referenceEPSS 3.2%

Medium (5.5) in tenda hg10 firmware. EPSS 3.2% estimated probability of exploitation activity in the next 30 days.

On this page
A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

Severity

CVSS 4.0

5.5 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P

CVSS 3.1

7.3 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
EPSS
3.2% (unchanged from 3.2% a week ago; 3.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 88th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: yes · Technical impact: partial, assessed 2026-01-30. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (Injection)
CWE-77 Improper Neutralization of Special Elements used in a Command
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-1687 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-1687?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-1687?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-1687 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Tenda HG10US_HG7_HG9_HG10re_300001138_en_xpon

Attack patterns (CAPEC)

  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-40 Manipulating Writeable Terminal Devices Likelihood: High · Severity: Very High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-75 Manipulating Writeable Configuration Files Likelihood: High · Severity: Very High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-136 LDAP Injection Likelihood: High · Severity: High
  • CAPEC-183 IMAP/SMTP Command Injection Severity: Medium
  • CAPEC-248 Command Injection Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-74 (37).

References

Check your stackJSON