cve.bz

CVE-2026-135789 D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection

8.5 high

High (8.5) in d-link r95.

On this page
A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Severity

CVSS 4.0

8.5 high
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P

CVSS 3.1

9.1 critical
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: total, assessed 2026-11-24. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-77 Improper Neutralization of Special Elements used in a Command
CWE-78 Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
Assigned by
VulDB (CNA)
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-135789 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-135789?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-135789?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-135789 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
D-Link R95101B06

Attack patterns (CAPEC)

  • CAPEC-6 Argument Injection Likelihood: High · Severity: High
  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-88 OS Command Injection Likelihood: High · Severity: High
  • CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High
  • CAPEC-40 Manipulating Writeable Terminal Devices Likelihood: High · Severity: Very High
  • CAPEC-75 Manipulating Writeable Configuration Files Likelihood: High · Severity: Very High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-136 LDAP Injection Likelihood: High · Severity: High
  • CAPEC-183 IMAP/SMTP Command Injection Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-77.

History

  1. Score 9.4 → 8.5 high
  2. The NVD deferred its analysis

Changes since this site first stored the record. The same for every record: /api/public/changes.

References

Check your stackJSON