cve.bz

CVE-2026-11405 tenda firmware

9.8 criticalEPSS 0.8%

Critical (9.8) in tenda firmware. EPSS 0.8% estimated probability of exploitation activity in the next 30 days.

On this page
The web server binary /bin/httpd contains a hidden backdoor authentication mechanism in the login() function at 004c88b8. - The function contains a normal authentication path using MD5/hash-based password verification (prod_encode64/PasswordToMd5/check_rand_key). - After normal authentication fails, it calls GetValue("sys.rzadmin.password") to read a backdoor password from the device configuration. - It performs a direct strcmp() comparison (plaintext, not hashed) between the config value and the user-supplied password. A successful match grants role=2 (admin-level access) and creates a valid session. The rzadmin username is never checked — any username works with the backdoor

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.8% (unchanged from 0.8% a week ago; 0.8% 30 days ago) estimated probability of exploitation activity in the next 30 days; 56th percentile. Scored 2026-11-15. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2026-07-08. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2026-11405 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2026-11405?via=ask-ai-copy and https://cve.bz/cve/CVE-2026-11405?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2026-11405 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Badge for a README or a site

CVE-2026-11405

An image that stays current: it is drawn from the data each time it is fetched (a host that proxies images, as GitHub does, may show its copy for a while). Markdown:

[![CVE-2026-11405](https://cve.bz/cve/badge/CVE-2026-11405.svg)](https://cve.bz/cve/CVE-2026-11405)

HTML:

<a href="https://cve.bz/cve/CVE-2026-11405"><img src="https://cve.bz/cve/badge/CVE-2026-11405.svg" alt="CVE-2026-11405"></a>

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Tenda firmwareUS_AC6V2.0RTL_V15.03.06.51_multi_T
Tenda firmwareUS_AC5V1.0RTL_V15.03.06.48_multi_TDE01
Tenda firmwareUS_AC10V1.0re_V15.03.06.46_multi_TDE01
Tenda firmwareUS_W15EV1.0br_V15.11.0.5(1068_1567_841)_EN_TDE
Tenda firmwareUS_FH1201V1.0BR_V1.2.0.14(408)_EN_TD

GitHub PoC (unverified)

Repositories on GitHub named after this CVE. Nobody has checked them and they are not scanned: some hold a working proof of concept, some nothing useful, and some malware made to look like one. Read the code before you run any of it.

References

Check your stackJSON