A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind. This vulnerability only affects products that are no longer supported by the maintainer.
12%(unchanged from 12% a week ago; 12% 30 days ago) estimated probability of exploitation activity in the next 30 days; 96th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: partial, assessed 2025-07-10. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-77Improper Neutralization of Special Elements used in a Command CWE-78Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
Show the promptExplain CVE-2025-7407 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-7407?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-7407?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-7407 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.
Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.
Emerging Threats Open ET WEB_SPECIFIC_APPS Netgear diag.cgi host_name Parameter Command Injection Attempt (CVE-2025-7407) sid 2067092
Attack patterns (CAPEC)
CAPEC-6 Argument Injection Likelihood: High · Severity: High
CAPEC-15 Command Delimiters Likelihood: High · Severity: High
CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
CAPEC-88 OS Command Injection Likelihood: High · Severity: High
CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High
CAPEC-40 Manipulating Writeable Terminal Devices Likelihood: High · Severity: Very High
CAPEC-75 Manipulating Writeable Configuration Files Likelihood: High · Severity: Very High
CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
CAPEC-136 LDAP Injection Likelihood: High · Severity: High
CAPEC-183 IMAP/SMTP Command Injection Severity: Medium
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-77.