CVE-2025-57528 tenda ac6 firmware: Improper Input Validation

7.7 highExploit referenceEPSS 0.4%

High (7.7) in tenda ac6 firmware. EPSS 0.4% estimated probability of exploitation activity in the next 30 days.

On this page
An issue was discovered in Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01 allowing attackers to cause a denial of service via the funcname, funcpara1, funcpara2 parameters to the formSetCfm function (uri path: SetCfm).

Severity

CVSS 3.1

7.7 high
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L
EPSS
0.4% (unchanged from 0.4% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 39th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: partial, assessed 2025-09-19. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-20 Improper Input Validation
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-57528 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-57528?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-57528?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-57528 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
tenda:ac6_firmware15.03.05.16

Detection rules

Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.

  • Emerging Threats Open ET WEB_SPECIFIC_APPS Tenda setcfm Multiple Parameters Buffer Overflow Attempt (CVE-2025-4298, CVE-2025-57528) sid 2064108

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-20 (51).

References

Check your stackJSON