An OS command injection vulnerability exists in PLDT WiFi Router's Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.
Severity
CVSS 3.1
5.3 medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
EPSS
1.7%(unchanged from 1.7% a week ago; 1.7% 30 days ago) estimated probability of exploitation activity in the next 30 days; 78th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: total, assessed 2025-09-03. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-78Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
Show the promptExplain CVE-2025-56498 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-56498?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-56498?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-56498 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.
Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.
Emerging Threats Open ET WEB_SPECIFIC_APPS PLDT formPing6 pingAddr Parameter Command Injection Attempt (CVE-2025-56498) sid 2064279
Attack patterns (CAPEC)
CAPEC-6 Argument Injection Likelihood: High · Severity: High
CAPEC-15 Command Delimiters Likelihood: High · Severity: High
CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
CAPEC-88 OS Command Injection Likelihood: High · Severity: High
CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.