cve.bz

CVE-2025-53698 johnson controls

7.0 high

High (7.0) in johnson controls.

On this page
Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC‑554: Functionality Bypass. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02.

Severity

CVSS 4.0

7.0 high
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CWE
CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface
Published
Assigned by
jci (CNA)
NVD analysis
Awaiting analysis
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-53698 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-53698?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-53698?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-53698 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Badge for a README or a site

CVE-2025-53698

An image that stays current: it is drawn from the data each time it is fetched (a host that proxies images, as GitHub does, may show its copy for a while). Markdown:

[![CVE-2025-53698](https://cve.bz/cve/badge/CVE-2025-53698.svg)](https://cve.bz/cve/CVE-2025-53698)

HTML:

<a href="https://cve.bz/cve/CVE-2025-53698"><img src="https://cve.bz/cve/badge/CVE-2025-53698.svg" alt="CVE-2025-53698"></a>

Affected

  • johnson controls:istar ultra
  • johnson controls:istar ultra se

Versions

From the CNA's record in the CVE List.

ProductAffected
Johnson Controls iSTAR Ultrabefore 6.9.2.CU02
Johnson Controls iSTAR Ultra SEbefore 6.9.2.CU02

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-224-02Johnson Controls iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 (Update A)2025-08-12Critical ManufacturingJohnson Controls iSTAR Ultra: <6.9.8, Johnson Controls iSTAR Ultra SE: <6.9.8none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-457 USB Memory Attacks Likelihood: Low · Severity: High
  • CAPEC-554 Functionality Bypass Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON