cve.bz

CVE-2025-46634 tenda rx2 pro firmware

8.2 highExploit referenceEPSS 0.2%

High (8.2) in tenda rx2 pro firmware. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collected traffic. It implements encryption, but not until after the user has transmitted the hash of their password in cleartext. The hash can be replayed to authenticate.

Severity

CVSS 3.1

8.2 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 7th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2025-05-02. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-312 Cleartext Storage of Sensitive Information
OWASP Top 10
A06:2025 Insecure Design
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-46634 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-46634?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-46634?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-46634 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
tenda:rx2_pro_firmware16.03.30.14

Attack patterns (CAPEC)

  • CAPEC-37 Retrieve Embedded Sensitive Data Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON