cve.bz

CVE-2025-40569 siemens: Race Condition

5.9 mediumEPSS 0.3%

Medium (5.9) in siemens. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

Severity

CVSS 4.0

5.9 medium
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N

CVSS 3.1

4.8 medium
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N
EPSS
0.3% (unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 23rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2025-06-10. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (Race Condition)
OWASP Top 10
A06:2025 Insecure Design
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-40569 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-40569?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-40569?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-40569 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens RUGGEDCOM RST2428Pbefore V3.2
Siemens SCALANCE XCH328before V3.2
Siemens SCALANCE XCM324before V3.2
Siemens SCALANCE XCM328before V3.2
Siemens SCALANCE XCM332before V3.2
Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC)before V3.2
Siemens SCALANCE XRM334 (230 V AC, 12xFO)before V3.2
Siemens SCALANCE XRM334 (230 V AC, 8xFO)before V3.2
Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)before V3.2
Siemens SCALANCE XRM334 (24 V DC, 12xFO)before V3.2
Siemens SCALANCE XRM334 (24 V DC, 8xFO)before V3.2
Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)before V3.2
Siemens SCALANCE XRM334 (2x230 V AC, 12xFO)before V3.2
Siemens SCALANCE XRM334 (2x230 V AC, 8xFO)before V3.2
Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)before V3.2

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-162-04Siemens SCALANCE and RUGGEDCOM2025-06-10Critical ManufacturingRUGGEDCOM RST2428P (6GK6242-6PA00), SCALANCE XCH328 (6GK5328-4TS01-2EC2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) and 12 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-26 Leveraging Race Conditions Likelihood: High · Severity: High
  • CAPEC-29 Leveraging Time-of-Check and Time-of-Use (TOCTOU) Race Conditions Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.