cve.bz

CVE-2025-3511 mitsubishi electric corporation

7.5 highEPSS 0.9%

High (7.5) in mitsubishi electric corporation. EPSS 0.9% estimated probability of exploitation activity in the next 30 days.

On this page
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
0.9% (unchanged from 0.9% a week ago; 0.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 62nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2025-10-23. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-1284 Improper Validation of Specified Quantity in Input
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-3511 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-3511?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-3511?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-3511 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-32D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-32T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-32D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-32T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GNCF1-32D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GNCF1-32T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GNCE3-32D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A4-16D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A2-16T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-16D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-16T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-16D09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-16T09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE09 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD407 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD407 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA407 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA407 and prior
Mitsubishi Electric Corporation CC-Link IE TSN FPGA module NZ2GN2S-D41P0101
Mitsubishi Electric Corporation CC-Link IE TSN FPGA module NZ2GN2S-D41D0101
Mitsubishi Electric Corporation CC-Link IE TSN FPGA module NZ2GN2S-D41PD0201
Mitsubishi Electric Corporation CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-3001.08J and prior
Mitsubishi Electric Corporation CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-601.08J and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T226 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP10 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX05 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series Ethernet Interface Module RJ71EN7185 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2GACP610-6005 and prior
Mitsubishi Electric Corporation CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2KT-NPETNG5105 and prior
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS1.020 and prior
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET1.200 and prior
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP1.106 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CPU module R04ENCPU (Network part)85 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CPU module R08ENCPU (Network part)85 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CPU module R16ENCPU (Network part)85 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CPU module R32ENCPU (Network part)85 and prior
Mitsubishi Electric Corporation MELSEC iQ-R Series CPU module R120ENCPU (Network part)85 and prior

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-128-03Mitsubishi Electric Multiple FA Products (Update D)2025-04-25Critical ManufacturingMitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE: <=09 and 46 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References

Check your stackJSON