An unauthenticated user with management network access can get and
modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20)
configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP
ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration
and execute some commands (e.g., system reboot).
Severity
CVSS 3.1
9.9 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L
EPSS
0.3%(unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 29th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2025-07-09. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-306Missing Authentication for Critical Functionality
Show the promptExplain CVE-2025-3498 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-3498?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-3498?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-3498 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.