cve.bz

CVE-2025-34196 vasion: Insufficiently Protected Credentials

9.3 criticalExploit referenceEPSS 0.5%

Critical (9.3) in vasion. EPSS 0.5% estimated probability of exploitation activity in the next 30 days.

On this page
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 25.1.102 and Application prior to 25.1.1413 (Windows client deployments) contain a hardcoded private key for the PrinterLogic Certificate Authority (CA) and a hardcoded password in product configuration files. The Windows client ships the CA certificate and its associated private key (and other sensitive settings such as a configured password) directly in shipped configuration files (for example clientsettings.dat and defaults.ini). An attacker who obtains these files can impersonate the CA, sign arbitrary certificates trusted by the Windows client, intercept or decrypt TLS-protected communications, and otherwise perform man-in-the-middle or impersonation attacks against the product's network communications. This vulnerability has been identified by the vendor as: V-2022-001 — Configuration File Contains CA & Private Key.

Severity

CVSS 4.0

9.3 critical
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.5% (unchanged from 0.5% a week ago; 0.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 42nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2025-09-30. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-522 Insufficiently Protected Credentials
CWE-798 Use of Hard-coded Credentials
OWASP Top 10
A06:2025 Insecure Design, A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2025-34196 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-34196?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-34196?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-34196 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Vasion Print Virtual Appliance Hostbefore 25.1.102
Vasion Print Applicationbefore 25.1.1413

Attack patterns (CAPEC)

  • CAPEC-70 Try Common or Default Usernames and Passwords Likelihood: Medium · Severity: High
  • CAPEC-191 Read Sensitive Constants Within an Executable Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-522 (13).

References

Check your stackJSON