cve.bz

CVE-2025-25675 tenda ac10 firmware: Code Injection

9.8 criticalEPSS 1.3%

Critical (9.8) in tenda ac10 firmware. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.

On this page
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 72nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2025-02-21. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-77 Improper Neutralization of Special Elements used in a Command
CWE-94 Improper Control of Generation of Code (Code Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-25675 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-25675?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-25675?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-25675 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
tenda:ac10_firmware15.03.06.23

Attack patterns (CAPEC)

  • CAPEC-35 Leverage Executable Code in Non-Executable Files Likelihood: High · Severity: Very High
  • CAPEC-77 Manipulating User-Controlled Variables Likelihood: High · Severity: Very High
  • CAPEC-242 Code Injection Likelihood: High · Severity: High
  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-40 Manipulating Writeable Terminal Devices Likelihood: High · Severity: Very High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-75 Manipulating Writeable Configuration Files Likelihood: High · Severity: Very High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-136 LDAP Injection Likelihood: High · Severity: High
  • CAPEC-183 IMAP/SMTP Command Injection Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-77.

References

Check your stackJSON