cve.bz

CVE-2025-24811 siemens: Improper Resource Shutdown or Release

8.7 highEPSS 0.6%

High (8.7) in siemens. EPSS 0.6% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device.

Severity

CVSS 4.0

8.7 high
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
0.6% (unchanged from 0.6% a week ago; 0.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 52nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2025-02-11. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-404 Improper Resource Shutdown or Release
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-24811 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-24811?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-24811?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-24811 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SIMATIC S7-1200 CPU 1211C AC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1211C DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1211C DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1212C AC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1212C DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1212C DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1214C AC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1214C DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1214C DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1215C AC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1215C DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1215C DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/DCbefore V4.7
Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/Rlybefore V4.7
Siemens SIMATIC S7-1200 CPU 1217C DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC RAILbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214C DC/DC/DC RAILbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLYbefore V4.7
Siemens SIPLUS S7-1200 CPU 1215C DC/DC/DCbefore V4.7
Siemens SIPLUS S7-1200 CPU 1215FC DC/DC/DCbefore V4.7

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-044-01Siemens SIMATIC S7-1200 CPU Family2025-02-11Critical ManufacturingSIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) and 45 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-125 Flooding Likelihood: High · Severity: Medium
  • CAPEC-130 Excessive Allocation Likelihood: Medium · Severity: Medium
  • CAPEC-131 Resource Leak Exposure Likelihood: Medium · Severity: Medium
  • CAPEC-494 TCP Fragmentation
  • CAPEC-495 UDP Fragmentation
  • CAPEC-496 ICMP Fragmentation
  • CAPEC-666 BlueSmacking Likelihood: Medium · Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON