cve.bz

CVE-2025-15574 solax power: Use of Insufficiently Random Values

6.5 mediumEPSS 0.2%

Medium (6.5) in solax power. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
When connecting to the Solax Cloud MQTT server the username is the "registration number", which is the 10 character string printed on the SolaX Power Pocket device / the QR code on the device. The password is derived from the "registration number" using a proprietary XOR/transposition algorithm. Attackers with the knowledge of the registration numbers can connect to the MQTT server and impersonate the dongle / inverters.

Severity

CVSS 3.1

6.5 medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 11th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2026-02-12. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-330 Use of Insufficiently Random Values
OWASP Top 10
A04:2025 Cryptographic Failures
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-15574 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-15574?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-15574?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-15574 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
SolaX Power Pocket WiFi 3.0<3.022.03
SolaX Power Pocket WiFi+LAN<1.009.02
SolaX Power Pocket WiFi+4GM<1.005.05
SolaX Power Pocket WiFi+LAN 2.0<006.06
SolaX Power Pocket WiFi 4.0<003.03

Attack patterns (CAPEC)

  • CAPEC-59 Session Credential Falsification through Prediction Likelihood: High · Severity: High
  • CAPEC-112 Brute Force Severity: High
  • CAPEC-485 Signature Spoofing by Key Recreation Likelihood: Low · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON