cve.bz

CVE-2025-15112 kseniasecurity lares firmware: Open Redirect

5.1 mediumEPSS 0.3%

Medium (5.1) in kseniasecurity lares firmware. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
Ksenia Security lares (legacy model) version 1.6 contains a URL redirection vulnerability in the 'cmdOk.xml' script that allows attackers to manipulate the 'redirectPage' GET parameter. Attackers can craft malicious links that redirect authenticated users to arbitrary websites when clicking on a specially constructed link hosted on a trusted domain.

Severity

CVSS 4.0

5.1 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N

CVSS 3.1

5.4 medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
EPSS
0.3% (unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 18th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: partial, assessed 2026-01-02. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-601 URL Redirection to Untrusted Site (Open Redirect)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-15112 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-15112?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-15112?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-15112 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
kseniasecurity:lares_firmware1.6

Attack patterns (CAPEC)

  • CAPEC-178 Cross-Site Flashing Likelihood: Medium · Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON