cve.bz

CVE-2025-13905 schneider electric: Incorrect Default Permissions

7.0 highEPSS 0.1%

High (7.0) in schneider electric. EPSS 0.1% estimated probability of exploitation activity in the next 30 days.

On this page
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.

Severity

CVSS 4.0

7.0 high
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS
0.1% (unchanged from 0.1% a week ago; 0.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 1st percentile. Scored 2026-11-23. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2026-01-29. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-276 Incorrect Default Permissions
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-13905 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-13905?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-13905?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-13905 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Schneider Electric EcoStruxure™ Process ExpertVersions prior to 2025
Schneider Electric EcoStruxure™ Process Expert for AVEVA System PlatformAll versions

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-26-022-01Schneider Electric EcoStruxure Process Expert (Update A)2026-01-13Critical Manufacturing, Energy, Commercial FacilitiesEcoStruxure Process Expert versions prior to 2025, EcoStruxure Process Expert for AVEVA System Platform versions prior to 2025EcoStruxure Process Expert 2025, EcoStruxure Process Expert for AVEVA System Platform version 2025

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs Likelihood: High · Severity: High
  • CAPEC-81 Web Server Logs Tampering Likelihood: Medium · Severity: High
  • CAPEC-127 Directory Indexing Likelihood: High · Severity: Medium