cve.bz

CVE-2025-11565 schneider electric powerchute™ serial shutdown: Path traversal

7.3 highEPSS 0.1%

High (7.3) in schneider electric powerchute™ serial shutdown. EPSS 0.1% estimated probability of exploitation activity in the next 30 days.

On this page
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.

Severity

CVSS 4.0

7.3 high
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS
0.1% (unchanged from 0.1% a week ago; 0.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 3rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2025-11-12. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-22 Improper Limitation of a Pathname to a Restricted Directory (Path traversal)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2025-11565 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2025-11565?via=ask-ai-copy and https://cve.bz/cve/CVE-2025-11565?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2025-11565 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Schneider Electric PowerChute™ Serial ShutdownVersions v1.3 and prior

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-322-04Schneider Electric PowerChute Serial Shutdown2025-11-11Critical ManufacturingPowerChute™ Serial Shutdown Versions v1.3 and priorPowerChute™ Serial Shutdown Version v1.4 installed on Microsoft Windows, PowerChute™ Serial Shutdown Version v1.4 installed on Red Hat Enterprise Linux, PowerChute™ Serial Shutdown Version v1.4 installed on SuSE Linux

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-126 Path Traversal Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON