cve.bz

CVE-2024-56182 siemens: Protection Mechanism Failure

8.4 highEPSS 0.2%

High (8.4) in siemens. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to disable the BIOS password without proper authorization by directly communicate with the flash controller.

Severity

CVSS 4.0

8.4 high
CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 3.1

8.2 high
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 12th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2025-03-11. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-693 Protection Mechanism Failure
OWASP Top 10
A06:2025 Insecure Design
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-56182 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-56182?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-56182?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-56182 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SIMATIC Field PG M5all versions
Siemens SIMATIC Field PG M6before V26.01.12
Siemens SIMATIC IPC BX-21Abefore V31.01.07
Siemens SIMATIC IPC BX-32Abefore V29.01.07
Siemens SIMATIC IPC BX-39Abefore V29.01.07
Siemens SIMATIC IPC BX-59Abefore V32.01.04
Siemens SIMATIC IPC PX-32Abefore V29.01.07
Siemens SIMATIC IPC PX-39Abefore V29.01.07
Siemens SIMATIC IPC PX-39A PRObefore V29.01.07
Siemens SIMATIC IPC RC-543Abefore V36.01.03
Siemens SIMATIC IPC RC-543Bbefore V35.01.12
Siemens SIMATIC IPC RW-543Abefore V1.1.4
Siemens SIMATIC IPC RW-543Bbefore V35.02.10
Siemens SIMATIC IPC127Ebefore V27.01.11
Siemens SIMATIC IPC227Eall versions
Siemens SIMATIC IPC227Gbefore V28.01.14
Siemens SIMATIC IPC277Eall versions
Siemens SIMATIC IPC277Gbefore V28.01.14
Siemens SIMATIC IPC277G PRObefore V28.01.14
Siemens SIMATIC IPC3000 SMART V3all versions
Siemens SIMATIC IPC327Gbefore V28.01.14
Siemens SIMATIC IPC347Gall versions
Siemens SIMATIC IPC377Gbefore V28.01.14
Siemens SIMATIC IPC427Ebefore V21.01.21
Siemens SIMATIC IPC477Ebefore V21.01.21
Siemens SIMATIC IPC477E PRObefore V21.01.21
Siemens SIMATIC IPC527Gall versions
Siemens SIMATIC IPC627Ebefore V25.02.15
Siemens SIMATIC IPC647Ebefore V25.02.15
Siemens SIMATIC IPC677Ebefore V25.02.15
Siemens SIMATIC IPC847Ebefore V25.02.15
Siemens SIMATIC ITP1000all versions

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-25-072-11Siemens SIMATIC IPC Family, ITP1000, and Field PGs2025-03-11Critical ManufacturingSIMATIC Field PG M5, SIMATIC IPC RC-543A < V36.01.03, SIMATIC IPC RC-543B < V35.01.12 and 29 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-693 (17).

References

Check your stackJSON