cve.bz

CVE-2024-54005 siemens

5.9 mediumEPSS 0.2%

Medium (5.9) in siemens. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.

Severity

CVSS 4.0

5.9 medium
CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

CVSS 3.1

5.1 medium
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 5th percentile. Scored 2026-11-23. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2024-12-10. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-611 Improper Restriction of XML External Entity Reference
OWASP Top 10
A02:2025 Security Misconfiguration
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-54005 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-54005?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-54005?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-54005 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens COMOS V10.3before V10.3.3.5.8
Siemens COMOS V10.4.0all versions
Siemens COMOS V10.4.1all versions
Siemens COMOS V10.4.2all versions
Siemens COMOS V10.4.3before V10.4.3.0.47
Siemens COMOS V10.4.4before V10.4.4.2
Siemens COMOS V10.4.4.1before V10.4.4.1.21

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-347-08Siemens COMOS2024-12-10Critical ManufacturingCOMOS V10.3, COMOS V10.4.0, COMOS V10.4.1 and 4 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-221 Data Serialization External Entities Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References